HydroScientific™

CARTRIDGE CLEANING INSTRUCTIONS
HydroScientific filter cartridges in most applications and micron ratings can be cleaned and reused. We suggest that you clean cartridges when pressure differential is 12-15 psi above the differential pressure at start-up. In the event cartridges are to be replaced, allow the pressure differential to climb to 25-30 psi above the start-up differential or when flow has diminished to an unacceptable level.
cartridge-cleaning

Cleaning Instructions –
Cartridge Cleaning in Aqueous Applications

Clean cartridges with a pressure nozzle using standard hose and direct spray at an angle to remove dirt, sand, silt and any other particulate matter.
Please follow these directions for best results:
NSF_site
APPLICATION FOR POTABLE WATER
  • Refer to www.nsf.org Approved citric acid (NSF Standard 60).
Organic matter-Algae-in-aqueous-solution
APPLICATION TO REMOVE ORGANIC MATTER AND ALGAE
  • Use tri-sodium phosphate or similar strong detergent (2 lbs. to 10 gallons of water), plus 1 pint of liquid chlorine to kill organic matter and algae.
  • Soak cartridges 1 hour or longer until surface is no longer slippery.
  • Rinse cartridge thoroughly with water.
Calcium-mineral-deposit
APPLICATION TO REMOVE CALCIUM & MINERAL DEPOSITS
  • Soak cartridges in a solution of tri-sodium phosphate or similar strong detergent (2 lbs. to 10 gallons of water).
  • Soak up to 12 hours.
  • Rinse cartridges thoroughly for approximately 10 minutes in a solution of one-part muriatic acid to 20 parts of water.
  • Rinse cartridge thoroughly with water.
tri-sodium
APPLICATION TO REMOVE OILS
  • Soak cartridges in a solution of tri-sodium phosphate or similar strong detergent (2 lbs. to 10 gallons of water).
  • Soak up to 12 hours.
  • Rinse cartridge thoroughly with water after soaking.
WARNING: DO NOT RINSE CARTRIDGES WITH ACID UNTIL OILS AND ORGANIC MATTER ARE REMOVED. USE DETERGENT FIRST AND FOLLOW WITH ACID SOAK FOR MINERAL REMOVAL. FLUSH CARTRIDGES WITH WATER AFTER MURIATIC OR TRI-SODIUM PHOSPHATE BATHS. GENERALLY, IT IS NOT POSSIBLE TO CLEAN HYDROSCIENTIFIC™ CARTRIDGES WHEN FILTERING PETROLEUM-BASED LIQUIDS AND TOXIC SUBSTANCES. DO NOT CLEAN CARTRIDGES THAT ARE ONE MICRON AND SUB-MICRON CARTRIDGES.
Note: These instructions are to be used as a guide. The data within has been obtained from many sources and is considered to be accurate. HydroScientific does not assume liability for the accuracy and/or completeness of this data. Changes to the data can be made without notification. Temperature, Pressure, Flow Rates, Differential Pressures, Chemical Combinations and other unknown factors can affect performance in unknown ways. Limited Warranty: HydroScientific warrants their products to be free of material and workmanship defects. Determination of suitability of HydroScientific products for uses and applications contemplated by Buyer shall be the sole responsibility of Buyer. The end user/installer/buyer shall be liable for the product’s performance and suitability regarding their specific intended applications. End users should perform their own tests to determine suitability for each application. © HydroScientific.